Please use this identifier to cite or link to this item: https://ptsldigital.ukm.my/jspui/handle/123456789/784386
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJuliah Theyirakumar-
dc.contributor.authorGeri Gopir-
dc.contributor.authorBaharudin Yatim-
dc.contributor.authorHilmi Sanusi-
dc.contributor.authorPuteri Safura Megat Mahmud-
dc.contributor.authorWoon Chin Yek-
dc.contributor.authorKelvin Tan Aik Boo-
dc.contributor.editorMahamod Ismail-
dc.date.accessioned2026-08-11T06:20:28Z-
dc.date.available2026-08-11T06:20:28Z-
dc.identifier.isbn978-1-4244-4956-9en_US
dc.identifier.urihttps://ptsldigital.ukm.my/jspui/handle/123456789/784386-
dc.description.abstractA newly designed multispectral ultraviolet (UV) sensor based on aluminium gallium nitride (AlGaN) photodiodes was calibrated using the solar UV radiation in three regions namely ultraviolet A (UVA), ultraviolet B (UVB) and ultraviolet C (UVC). This UV sensor which was transimpedance amplifier system, designed with measures the de voltage output of direct solar UVA, UVB and UVC radiation (VA,VB and Vc) in Bangi, Malaysia (2.92 °N, 101.78 °E, 50 m above sea level). For calibration, this designed UV sensor a were used to measure simultaneously with a silicon-based UVA Light Sensor designed with PASCO PASPORT interface, Xplorer GLX Datalogger which measures the UVA radiation intensity, LA. As a result, a linear relationships between the multispectral UV voltages and UVA intensity were obtained and thus, three linear equations of UVA, UVB and UVC radiation intensity as a function of the multispectral UV voltages were derived. Intensity ratios between the three UV region were deduced from the derived intensity equations. The multispectral UV radiation voltages were further analyzed by plotting the UV voltage values with time. Thus, the multispectral UV sensor based on the AlGaN photodiodes was able to be calibrated successfully.en_US
dc.language.isoenen_US
dc.subjectSolar ultraviolet radiationen_US
dc.subjectTransimpedance amplifieren_US
dc.subjectMultispectral UV sensoren_US
dc.subjectAlGaN photodiodesen_US
dc.titleCalibration of a newly designed multispectral ultraviolet sensor based on AlGaN photodiodes using solar radiationen_US
dc.typeSeminar Papersen_US
dc.format.pages102-107en_US
dc.identifier.callnoQB495.I557 2009 semen_US
dc.contributor.conferencenameInternational Conference on Space Science & Communication (IconSpace)-
dc.coverage.conferencelocationThistle Port Dickson Resort, Negeri Sembilan-
dc.date.conferencedate2009-10-26-