Please use this identifier to cite or link to this item: https://ptsldigital.ukm.my/jspui/handle/123456789/578385
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAzli Baharudin
dc.contributor.authorMohamad Hasnan Ahmad
dc.contributor.authorBalkish Mahadir Naidu
dc.contributor.authorNurul Rufaidah Hamzah (UITM)
dc.contributor.authorNor Azian Mohd Zaki
dc.contributor.authorAhmad Ali Zainuddin (UITM)
dc.contributor.authorNoor Safiza Mohd Nor
dc.date.accessioned2023-11-06T03:01:05Z-
dc.date.available2023-11-06T03:01:05Z-
dc.date.issued2017-07
dc.identifier.issn0128-7680
dc.identifier.otherukmvital:115885
dc.identifier.urihttps://ptsldigital.ukm.my/jspui/handle/123456789/578385-
dc.descriptionThis study sought to examine the reliability and validity of height measurements using a portable stadiometer as compared to a mechanical scale. Samples from 142 adults aged 22 to 57 were taken during data collection in November 2014. There was a high degree of reliability for the inter-examiner, intraexaminer and inter-instrument aspects with regards to mean difference, the inter correlation coefficient (ICC) and Bland-Altman Plot. For the inter-examiner aspect, the height measurement taken by the first examiner was 0.01 cm higher than that by the second examiner with an ICC of 0.999. For the intraexaminer aspect, the difference was 0.1 cm; this was higher in the first measurement compared to the second. The ICC was also 0.999. For the inter-instrument aspect, measurement taken by stadiometer was 0.61 cm higher than the measurement taken by mechanical scale and the ICC was 0.997. The Bland-Altman plot showed a distribution of differences between measurements in the inter-examiner, intraexaminer and inter-instrument aspects that were close to zero within the narrow range of ±1.96SD. The technical error of measurement (TEM), coefficient of reliability (R) and coefficient of variation (CV) for the inter-examiner, intra-examiner and inter-instrument aspects were within the acceptable limits. This study suggests that the portable stadiometer is reliable and valid for use in community surveys.
dc.language.isoen
dc.publisherUniversiti Putra Malaysia Press
dc.relation.haspartPertanika Journals
dc.relation.urihttp://www.pertanika.upm.edu.my/regular_issues.php?jtype=2&journal=JST-25-3-7
dc.rightsUKM
dc.subjectStadiometer
dc.subjectReliability
dc.subjectTechnical error of measurement
dc.subjectvalidity of height
dc.titleReliability, technical error of measurement and validity of height measurement using portable stadiometer
dc.typeJournal Article
dc.format.volume25
dc.format.pages675-686
dc.format.issue3
Appears in Collections:Journal Content Pages/ Kandungan Halaman Jurnal

Files in This Item:
File Description SizeFormat 
ukmvital_115885+Source01+Source010.PDF507.58 kBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.