Please use this identifier to cite or link to this item:
https://ptsldigital.ukm.my/jspui/handle/123456789/578268
Title: | Developing a user-friendly procedure in quantifying interior lighting |
Authors: | Amirul Ad-din Majid (UITM) Ahmad Mursyid Ahmad Rudin (UITM) Ai-Hong Chen (UITM) |
Keywords: | Illuminance Interior lighting Lux meter Lighting quantification Zig-zag pattern |
Issue Date: | Aug-2017 |
Description: | The purpose of this study was to develop a simple, economical but efficient procedure to collect illuminance data in quantifying interior lighting. This study was carried out in 3.8 m × 2.9 m × 3.0 m controlled experimental room. Three approaches to measure illuminance level were examined: (1) rowto-row; (2) column-to-column; and (3) zig-zag direction. A pre-determined 34 measurement points was used for all the three approaches. The duration required to complete the illuminance data measurement was recorded in minutes. There was a statistically significant difference in the total time measured to complete the illuminance data measurement in three different approaches (F(2, 4) = 23266.81, p<0.05). The finding concluded that the zig-zag direction approach was the fastest and most efficient way in quantifying interior lighting. |
News Source: | Pertanika Journals |
ISSN: | 0128-7680 |
Volume: | 25 |
Pages: | 163-172 |
Publisher: | Universiti Putra Malaysia Press |
Appears in Collections: | Journal Content Pages/ Kandungan Halaman Jurnal |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
ukmvital_115790+Source01+Source010.PDF | 2.84 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.